Data centers depend on water to operate their cooling systems, whose main function is to prevent the overheating of structural components. This water circulates through pipes, sometimes evaporating or circulating repeatedly internally in other cases.
Any type of dirt, such as salt from saltwater, can accumulate rapidly in this system. Charles Domingues, a chemist and consultant for Abrava (Brazilian Association of Refrigeration, Air Conditioning, Ventilation, and Heating), warns that using dirty water goes beyond aesthetic issues, representing a physical, chemical, and reliability risk.
Domingues details that these contaminants can trigger chemical reactions, lead to pipe obstruction, cause rust in structures, and promote the development of microorganism colonies.
Generally, data centers are supplied by conventional public system water, also used by residences, businesses, and industries. Luis Tossi, Vice President of the Brazilian Association of Data Centers, clarifies that the circuit must be fed with treated water, to which specific products can be added to prevent corrosion, deposit formation, and microorganism proliferation. This water circulates, transports heat from the equipment to a dissipation system, and then returns to restart the cycle.
In Brazil, there is no precise data on the proportion of data centers that use potable water for cooling. However, it is known that approximately 80% operate with closed systems, resulting in lower water consumption, while only 20% use open systems, where evaporation occurs.
Tossi emphasizes that the main advantage of closed systems is the ability for the water to circulate for long periods with only occasional maintenance and replenishment, allowing for a significant reduction in water consumption, depending on the heat dissipation technology used.
Domingues adds that regardless of the arrangement—whether closed, semi-open with return, or a combination—the water maintains continuous and permanent contact with condensers, heat exchangers, circulation pumps, and pipes, and it is at this water-metal interface that the system's durability is determined.
Although the water consumption of Brazilian data centers is still modest compared to the total volume consumed by other activities in the country, there is concern that, in regions already affected by water scarcity, data centers may compete with human needs for this resource.
However, there are initiatives that use recycled water, such as treated sewage, to cool data centers. Google reports using recycled or non-potable water in over 25% of its facilities. Amazon Web Services (AWS) states that it uses recycled water in 26 of its global data centers and plans to expand this use to another 130. Although the company does not disclose the exact number of its data centers, it is estimated to be 900.
Currently, the use of recovered water is still an exception. However, there is a promising study that reverses the logic of the issue: researchers are investigating the viability of converting heat generated by data centers into energy. This energy can be used to treat effluents or desalinate water, processes that are typically energy-intensive. Thus, this treated water could, in turn, supply the cooling system of the data center itself.