When considering building-integrated photovoltaic systems (BIPV), the enormous potential is evident: transforming the building envelope into an active part of its energy strategy. However, specifying such systems can be complex if the process is unfamiliar. Questions arise: how much electricity can the facade generate? What will the system cost? Which orientations and zones are suitable? And how must the photovoltaic panels comply with the building's structural, electrical requirements, and fire safety regulations?
Without clear answers, assessing feasibility, creating estimates, and engaging consultants and construction companies can become a difficult task. An integrated design process helps reduce these uncertainties. Companies like SolarLab collaborate with architectural and engineering teams from the earliest stages of a project, utilizing design tools, energy modeling, cost assessment, technical support, and testing for a clearer understanding of each site's requirements.
Facade Designed in Collaboration
The innovative Fanshawe College settlement in London, Ontario, demonstrates how such collaboration can be realized in a viable structural system. The project, designed by Diamond Schmitt, unites previously disparate parts of the university campus into a center for learning, research, and collaboration. Its facade features a custom-designed photovoltaic cladding system on all sides, including the north facade.
Using BIPV in all directions required the design team to consider panel tilt angle, energy generation, and the technical requirements of a ventilated facade system. The resulting system combines active and passive, custom-made low-iron glass panels. The alternation of upward-tilted photovoltaic panels with smaller, recessed passive elements creates a unique geometry, while the surface color subtly changes depending on the lighting.
SolarLab worked alongside Diamond Schmitt and the overall project team to provide the facade system. Each active panel incorporates photovoltaic elements in laminated safety glass, supported by a high-precision aluminum substructure designed for local wind and snow loads. Concealed fixings, the ventilated gap, and the coordination of panel sizes and connections were also considered during the development of the building envelope.
On the construction site, detailed mock-ups were created to assess the fit and alignment of the facade components. Since the panels were manufactured outside of Canada, component testing was conducted both on-site and off-site, parallel to certification required by Canadian standards. The photovoltaic cladding also required coordination with the load-bearing wall system, including insulation, substructure, weather barriers, and fire barriers.
The completed facade structure has a nominal capacity of 174.86 kWp with a projected annual energy generation of 122.98 MWh. The system is expected to cover about 18% of the building's current energy needs. Combined with roof-mounted panels, the combined technologies should meet approximately 30% of the building's total energy consumption. Preliminary cost-benefit analysis helped confirm the feasibility of implementation.
Transparency of Processes, Performance, and Costs
Energy modeling helps design teams understand how solar radiation changes across the building depending on orientation, external obstructions, panel tilt angle, size, and surface treatment. Using contextual 3D models and local climate data, SolarLab can estimate solar radiation and expected energy production throughout the year. Visualizations and data graphs allow teams to compare configurations and assess how panel placement contributes to achieving the building's energy goals.
The level of detail evolves as the project progresses: from initial production estimates to more detailed calculations as the design and panel layout are defined. SolarLab's tools for Rhino and Grasshopper, combined with their CAD and BIM functions, allow architects to explore facade configurations and assess performance even at the research stage. An online calculator provides a preliminary estimate of material costs for solar facades, while a more detailed energy generation estimate can be developed through specific calculations and simulations for each project. This helps determine where photovoltaic panels are most effective, without needing to cover all available facade surfaces, and clarifies the relationship between design decisions, expected generation, and return on investment.
Compliance with Technical and Regulatory Requirements
As the project develops, cable routing, fixing rails, connections, tolerances, ventilation cavities, monitoring, and maintenance must be coordinated with structural and fire protection requirements. In ventilated facades, the cavity and its connection to electrical components must be considered within the overall fire safety strategy, including fire barriers, material specifications, and local building codes.
Technical testing is another way to assess these requirements and reduce uncertainty regarding fire safety. According to SolarLab, a polymer sealing layer approximately 0.9 mm thick protecting the photovoltaic elements prevents solar panels—whether traditional or building-integrated—from achieving A2 classification according to European standard EN 13501-1:2018. On the other hand, their glass-to-glass and glass-backsheet type panels achieved B-s1,d0 classification.
Understanding this limitation early allows for the correct design of facade details and the development of a comprehensive fire safety strategy from the earliest project phases, minimizing risks. If necessary, special tests for the project can certify performance according to local codes. For their 'System 25', SolarLab has also undergone testing according to NFPA 285 and NFPA 268 standards. Additional module tests evaluate the impact of hail, wet current leakage, and the reliability of electrical terminals. Other certifications for international markets, including the US and Canada, are in progress, with new tests scheduled for 2027.
Beyond fire safety and regulatory compliance, aligning technical requirements with an ambitious architectural vision is key to realizing high-performance facade systems. The Student Experience International building in Amsterdam, designed by VURB Architects, demonstrates how collaboration between designers and facade specialists, such as SolarLab, can help mitigate risks in highly technically complex projects during the development and construction of photovoltaic facades. Over 3000 square meters of individually tilted solar panels cover the building envelope with a peak capacity of approximately 283 kWp. The satin finish and horizontal rotation of the modules create variable shades of gray-blue and gray-silver depending on the sun's movement, limiting glare. A limited range of panel formats and a flexible mounting system contribute to durability and maintenance. Integrating energy generation into the envelope also frees up the roof for green spaces and outdoor public events.
Collectively, these projects show that reducing risks in BIPV systems is a collaborative process that covers all stages: from initial feasibility to architectural design, engineering, testing, and installation. Ensuring transparency in costs, energy performance, technical limitations, and regulatory requirements at every stage gives architects and project partners a stronger foundation for evaluating and implementing solar facades.